Labmark
products

Product Pricelist
need a password?

Model - Mini Heating Block / Digestor

Double Heating Block

Heating Block and Controller
LABCON mini heating block / digestor units are suitable for COD's, thermal digestions and general test tube heating applications in the temperature range of ambient +5ºC to 200ºC. Temperature control is microprocessor controlled using PT100 input sensor and a solid state relay output. A three position setpoint selector switch selects either one of two preset temperatures or a continuously variable setpoint control.The preset temperatures are factory set to 100ºC and 148ºC respectively, and are user adjustable to any temperature within the range of ambient +5ºC to 200ºC. A selectable timer, 0-120 minute, for automatic shut-off is also fitted as standard. Aluminium block area - 120 x 120mm. Hole depth - 55mm.

OPTIONS:- A unit with two moveable blocks as shown on the right
TEMPERATURE RANGE:- Ambient +5ºC to 200ºC
CONTROL ACCURACY:- ± 0.2ºC @ 100º


Model Holes Dimensions Power Weight
Kg
No. 0mm W D H Voltage Kw
MHB25/16 25 16.5 135 250 265 220/240 0.5 6.5
MHB16/22 16 22 135 250 265 220/240 0.5 6.5
MHB36/11C 25 11 conical 135 250 265 220/240 0.5 6.5


model - Mini Heating Block / Digestor
Labcon heating block / digestor units are suitable for COD's, thermal digestions and general test tube heating applications. Digestors consist of three parts:- The electronic control unit, the heating block unit and the test tube rack if required. The remote cables between the microprocessor control unit and the heating block are 1.5m long. Control units and heating blocks are interchangeable.

Microprocessor Control Unit:-
incorporates a microprocessor controlled temperature indicator, a selectable timer, 0-12- minutes for automatic shut-off, a three position setpoint selector switch which selects either one of two preset temperatures or a continuously variable setpoint control. The preset temperatures are factory set to 100ºC and 148ºC respectively, and are user adjustable to any temperature within the operating temperature range of the specific model.

model - Controller
DCA 45 - temperature range +50ºC to 450ºC
DCA 20 - temperature range Ambient +5ºC to 200˚C

CONTROL ACCURACY:- ± 0.2ºC @ 100ºC

Heating Block Units:-
Machined aluminium block housed in a well insulated powder coated mild steel housing with stainless steel surround. The element is a easily replaceable clamp on type incaloy element.

Model:- Single block units
D18 - 18 HOLES x 47 ø 60mm DEEP
D21 - 21 HOLES x 34 ø 60mm DEEP
D40 - 40 HOLES x 28 ø 60mm DEEP
D60 - 60 HOLES x 23 ø 60mm DEEP
D105 -105 HOLES x 16 ø 60mm DEEP

Model:- Double block units
D18/2 - 36 HOLES x 47 ø 60mm DEEP
D21/2 - 42 HOLES x 34 ø 60mm DEEP
D40/2 - 80 HOLES x 28 ø 60mm DEEP
D60/2 -120 HOLES x 23 ø 60mm DEEP
D105/2 -210 HOLES x 16 ø 60mm DEEP

Test tube racks:-
STANDARD - All stainless steel with three sides double walled and insulated plus toughened glass front safety shield.

ECONOMY - All stainless steel with single walled sides and open front and back.

Model Dimensions Power Weight
Kg
W D H Voltage Kw
DCA Control Unit 140 275 260 220/240 0.1 4.5
Single Block Unit 180 580 270 220/240 2.0 19.5
Double Block Unit 180 580 430 220/240 3.0 37.0
Single Rack Standard 330 450 220     6.5
Double Rack Standard 330 450 355     8.5
Single Rack Economy 230 420 165     1.3
Double Rack Economy 230 420 320     2.5


Tel: local (011) 472 3720    overseas +27 11 472 3720   |    Fax: local (011) 672 6549    overseas +27 11 672 6549    |    labmark@global.co.za