Ultra Sonic Baths
Labcon Ultrasonic Baths have been designed and manufactured to the highest standards and include the following standard features:
  • 304 Seamless stainless steel inner tank
  • Powder coated mild steel outer housing
  • Microprocessor controller (LED display) with the following features:
  • Timer
  • Auto power cut out
  • Automatic saving of program following power failure
  • Programmable options ( up to 8 )
  • Start / Stop
  • Variable power utilization with indicator
  • Temperature indicator - "Set" and "Actual"
  • "Sandwich" transducers
  • Operating frequency approximating 40KHz
  • Optimum filling level mark in tank
  • Heating
    Caution:
  • When using a cleaning solution, care should be taken to ensure that the correct one designed for the specific application is used so as to ensure that no damage to articles is caused ( e.g. light metals such as chrome - and nickel plated objects);
  • Water without an appropriate cleaning solution added thereto will not clean as effectively;
  • The tank should be filled to the level indicated (indentation in tank) so as to ensure optimal performance;
  • Objects should not be placed on the floor of the tank. They should be placed in suitable holders.
Every effort has been taken to ensure the accuracy of this specification. However, due to continuous development and improvement the goods supplied may vary in detail from those described or illustrated. The Labcon Utrasonic bath is manufactured under license by Laboratory Marketing Services (Pty) Ltd.

MODEL DIMENSIONS VOLUME
lt (approx)
DRAIN
(ball cock)
HF - peak
ouput
(w/per)
POWER
SUPPLY
WEIGHT
KG
(approx)
EXTERNAL INTERNAL
H W D H W D KW VOLT
UBM 2 300 192 178 100 150 135 2 N 2 x 100W 220/240 4.8
UBM 8 340 342 192 195 295 150 8 Y 2 x 200W 220/240 7.5
UBM 11 340 342 282 195 295 240 11 Y 2 x 400W 220/240 9.2
UBM 22 340 540 335 195 495 295 22 Y 2 x 600W 220/240 18.6


Accessories
Lid for bath: made from 304 stainless steel and fitted with rubber stoppers to suppress noise from vibration

Insert baskets: made from steel mesh (chromed). The handles are designed to fit over the lip of the bath

Test tube rack: made from 304 stainless steel and fitted with rubber stoppers at the base to prevent surface contact with the base of the tank. Designed for 100mm, 150mm or 200mm depth tanks, the diameters of the holes provide for flexible configurations to user specification from 16mm to 25mm.

Clamps: designed to hold Erlenmeyer flasks. They may be fitted into the insert baskets

Beaker rack: made from 304 stainless steel, beakers may be inserted. The rack is fitted with a lip to secure it over the top of the bath. A rubber band is provided to hold beakers at the desired height.

Sieve rack: made from 304 stainless steel, it secures sieves while being cleaned.

ITEM UBM2 UBM 8 UBM 11 UBM 22
lid item code: Z 932 item code: Z 933 item code: Z 934 item code: Z 935
insert baskets item code: Z 936 item code: Z 937 item code: Z 938 item code: Z 939
test tube rack item code: N/A item code: N/A item code: Z 940 clamps item code: Z 941
clamps item code: N/A item code: N/A item code: Z 942 item code: Z 943
beaker rack item code: Z 944 item code: Z 945 item code: Z 946 item code: Z 947
sieve rack item code: N/A item code: N/A item code: N/A item code: Z 948


CLEANING AND DISINFECTING
To enhance cleaning, it is recommended that a special purpose cleaning or disinfecting liquid solution be used. Care should be taken to ensure that the correct solution is used or the desired cleaning effect may not be achieved. The possibility of damage to articles being cleaned or disinfected and to the stainless steel tank, exists.

Care should be taken to ensure that the solution to be used is suitable for:
  • disinfecting ( e.g. of fungicides ). Always ensure that the appropriate certification has been granted, such as a CE- mark according to CE-Directive (e.g.93/42 EEC for medical devices ), and/or approval by a certified, licensed or authorised agency;
  • pre-cleaning and/or basic cleaning and/or intensive cleaning;
  • that the characteristics of the solution conform to benchmark standards - excluding aldehydes (y/n); excluding phenol (y/n/); excluding chlorine (y/n); the removal of contaminants such as secretians, blood, incrustations, etc.;
  • the material being cleaned, e.g.: Steel • Rubber • Acrylic • Stainless Steel • Light Metal • Tin • Zinc • Certain Alloys • Acrylic glass • Glass • Plastic • PVC • Precious Metals
We recommend that you consult your distributor / agent for an appropriate recommendation.
    GENERAL INFORMATION ABOUT ULTRASONIC CLEANING
  • Ultrasound occurs at frequencies above 18KHz. Typically, cleaning action occurs from 27KHz to 40KHz.
  • The vibrations cause tiny vacuum bubbles to form resulting in the "cold boiling" of water. As a result, the bubbles implode creating a "pressure push" which causes particles adhering to a surface of an object to be removed.
  • The vibrations in the water are produced by an electro mechanical device called a transducer, which is secured to the outside surface of the tank.
  • Ultrasound produces a cleaning action which penetrates holes, pores and cavities. It cleans thoroughly in a relatively short time, and produces a gentle cleaning action which protects the surface of the object being cleaned. Used in conjunction with a cleaning agent it is a highly efficient and effective process.
  • Cleaning solutions which are heated reduce cleaning time. However, care should be taken when using disinfecting solutions at temperatures in excess of 40degC because of coagulation.
Tel: local (011) 472 3720    overseas +27 11 472 3720   |    Fax: local (011) 672 6549    overseas +27 11 672 6549    |    labmark@global.co.za
© Copyright Labmark Laboratory Marketing Services (Pty) Ltd . All Rights Reserved.